Rev Australasia V2.3 12/04
21 21
configuration settings. Configurator® comprises a single window display within which all
options are listed and all possible settings are viewable in drop-down menu boxes.
The Configurator® program will automatically determine the communications settings that
are effective in the Panel Reader. The factory default settings are 9600 bits/second, no parity,
8 bits/word, 1 stop bit, and no flow control. If these parameters are changed by the user, these
settings will be automatically detected by Configurator®.
The settings should automatically appear
from the reader in the boxes of the
program. However, if not – select the
GET SETTINGS icon or select the
READER button and the then GET
SETTINGS (F2 Key). This will bring the
settings into the program.
After the settings have been brought into
the Configurator® Program, make the
appropriate changes you desire. Then you
will need to apply these settings. To do
this, select the APPLY SETTING icon, or
select READER and then APPLY SETTINGS or press the F3 key.
A typical example of where changing a setting might be necessary is to change the reader so
that it sends duplicates, or perhaps, not to send duplicate reads. This means that if a beast gets
read 20 times as it walks past an antenna, the reader will transmit the number 20 times to the
computer / scale head. Some scale heads are set for this such as the Trutest XR and SR series.
Some other brands such as the Ruddweigh 500 and 600 series require the number once only.
Therefore, in Australia and New Zealand, the Factory Default Settings are changed just in
case the reader will be connected to a Ruddweigh system. This means that the Send
Duplicates function is set to “Don’t Send’
If you have to change this setting, or if your panel gets accidentally set back to factory default
settings, you can change the Send
Duplicates function by the following
process. Use this as an example for
changing any settings you need to
change.
Select the function you wish to
change such as “Send Duplicates”.
Use the down arrow at the end of the
box to list the options. Select the
Option you require – such as “Don’t
Send”. Then Select the APPLY
SETTINGS icon.
Generally, this is the only setting
that requires changing in Australia
or New Zealand.
If you require assistance with any
other setting – please call your local
Allflex Office.
Komentarze do niniejszej Instrukcji